 Yes, you want the heaviest wired groundloop you can get. It doesn't necessary 
improve your RF ground (as that really never exist) but it will help out 
redirecting current in case of a lightning strike in you buildings or nearby.

When you implement it don't forget that you can include you water supply system 
and your heating system (if you have water carried heat in copper pipes like I 
have).

I believe the idea is that you try to reduce the voltage differences across 
your house a much as possible thereby not getting damages from the lightning 
current.

Imagine if you could build your house on a large, thick metals plate of some 
good conducting material. That would act like a gigantic, electric island that 
would reduce and voltage differences between the corners of your house. If you 
then shields around every electric (and electronic) equipment in the house and 
connected these shields to the gigantic metal plate under the house you would 
have the ultimate lightning protection.

Now, the heavy conductor around your house will (try to) act like the gigantic 
plate and give you some protection.

Needless to say, you connect your tower to that ground loop to include it in 
the, hopefully so, voltage reduction scheme. 

Good luck in your endeavor and 73 de, 

Hans - N2JFS

 

 


-----Original Message-----
From: TowerTalk [mailto:towertalk-bounces@contesting.com] On Behalf Of Dick
Blumenstein
Sent: Sunday, July 24, 2016 16:04
To: TowerTalk@contesting.com
Subject: [TowerTalk] Does prevailing grounding scheme promote large ground
loop?

 From everything I've read, the prevailing overall grounding technique is to
run a heavy duty copper wire from the grounding system around the tower,
back to the ground rod outside the shack wall as well as to run it to the
ground rod under where your AC power enters the house.

It just occurred to me that the AC ground wire, besides going into the house
and connecting to the chassis ground in the breaker box (where also all the
neutral white wires are connected) then proceeds throughout your house and
also to your ham radio shack equipment. It is here that the ground wire also
connects to all the chassis in your shack as well as the shields on your
coax connectors that also finds it way back outside your shack wall to the
ground rod; one huge ground loop.  I know that there are 2 issues here; RF
grounding and lightning protection. Any comments about that?

Thanks,

Dick, K0CAT




_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk

<Prev in Thread] Current Thread [Next in Thread>