Towertalk
[Top] [All Lists]

Re: [TowerTalk] Prosistel rotor connectors source in USA

To: "'Jorge Diez - CX6VM'" <cx6vm.jorge@gmail.com>
Subject: Re: [TowerTalk] Prosistel rotor connectors source in USA
From: "Jeff DePolo" <jd0@broadsci.com>
Date: Sun, 23 Mar 2025 16:50:36 -0400
List-post: <mailto:towertalk@contesting.com>
I’m confused – 4 pairs is 8 wires.  There was mention made of using Cat7 which 
is also 4 pairs/8 wires, but doubling up on some of them, presumably for 
higher-current motor power.  What am I missing here?
 
                                                                                
--- Jeff WN3A
 
From: Jorge Diez - CX6VM <cx6vm.jorge@gmail.com> 
Sent: Sunday, March 23, 2025 3:53 PM
To: Jeff DePolo <jd0@broadsci.com>
Cc: jim@audiosystemsgroup.com; towertalk@contesting.com
Subject: Re: [TowerTalk] Prosistel rotor connectors source in USA
 
Hello Jeff
 
but this Essex BBDG6A cable seems to be 4 pairs, we need 5 wires for Prosistel 
 
73,
Jorge
 
El dom, 23 mar 2025 a las 15:11, Jeff DePolo (<jd0@broadsci.com 
<mailto:jd0@broadsci.com> >) escribió:
> > Prosistel recommends Cat7E for the motor conductors?  Cat7E uses 23 or
22
> > awg copper wires.  I am not familiar with Prosistel rotators and I don't
> > know the motor's voltage or amperage.  22awg wire has 1.6 ohms
resistance
> > per 100 feet so the voltage drop at the motor could be significant.

I think Prosistel recommends shielded Cat7 because they use an encoder for
position tracking; the controller could be susceptible to RFI on those
conductors, thus the requirement for shielding and twist?  As far as power
requirements, I don't know, but if you can get away with it, I'd use
something like Essex BBDG6A which is also 23 gauge, is flooded (icky-pic),
has a copper armor shield that you can put ground kits on, and has a very
tough jacket.  We use it all the time on towers for Ethernet to microwave
radios.  It's good stuff, and not all that expensive in full-reel
quantities.

> Mass market options for multi-conductor cable are pretty limited. I used
> two runs of Romex for most of the 350 ft run to the top of my tower for
> a Yaesu rotator.

For Yaesu we use TC-ER tray cable.  Wire And Cable Your Way has good
selection and will cut to any length.  For quick and dirty temporary use,
sprinkler wire...

                                        --- Jeff WN3A

---------------------------------
Jeff DePolo, Senior Engineer
Broadcast Sciences LLC
Valley Forge, Pennsylvania
610.917.3000
  





_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com <mailto:TowerTalk@contesting.com> 
http://lists.contesting.com/mailman/listinfo/towertalk


 
-- 
73,
Jorge
CX6VM/CW5W
_______________________________________________



_______________________________________________
TowerTalk mailing list
TowerTalk@contesting.com
http://lists.contesting.com/mailman/listinfo/towertalk
<Prev in Thread] Current Thread [Next in Thread>