You are very likely to get a response from K7LXC on this one. I agree with him
that unless the cable shows some indication of imminent breakdown (broken
strands, excessive corrosion, etc.) it is probably still ok. My Triex 72 ft
crank up had the original winch cable on it when it blew down 3 years ago. It
was over 20 years old. My current US Tower 72ft motorized tower, which is about
15 YO, still has the original cables on it.
I have purchased a replacement cable set and will put them on some day. I
inspect the cables regularly and they always look fine to me. I believe that
UST recommends every 3 years, but that is probably out of concerns for
liability. On the US Towers, you have the option of stopping the tower resting
location at different points and that helps extend the cable life by shifting
the pully stress points on the cables.
I apply wire rope lube (spray on) to all my winch cables and that helps extend
the life many years.Be sure and use this stuff.
John Owens - N7TK