[TowerTalk] Odd guying problem, a question for the engineers

To: <towertalk@contesting.com>
Subject: [TowerTalk] Odd guying problem, a question for the engineers
From: "jeremy-ca" <km1h@jeremy.mv.com>
Date: Sat, 11 Aug 2007 13:02:34 -0400
List-post: <mailto:towertalk@contesting.com>
One lower 1/4" EHS guy on my 180' 45G needs to be raised a few feet to give 
clearance to trucks going to the rear of my property.

I was thinking of attaching it to the next higher guy about 4' up from the 
guy anchor turnbuckle. Since the 1/2" turnbuckle and 1/4" EHS are over spec 
for the tower Im hoping that this wont be a problem. I propose to attach the 
lower turnbuckle to the upper guy wire with a Big Grip or a piece of EHS and 
clamps if the angle is a problem. I want this to be a permanent solution.

Comments?

Carl
KM1H 