Towertalk
[Top] [All Lists]

[TowerTalk] coax and phasing

To: <towertalk@contesting.com>
Subject: [TowerTalk] coax and phasing
From: philk5pc@tyler.net (Phil Clements)
Date: Mon, 13 Sep 1999 14:37:36 -0500
I would not try to push more than 500 watts @ 20m through the RG-8X, Lane.
Otherwise, no problem.
Remember the velocity factor is different from solid dilectric coax ((RG-214)

GL!
Phil, K5PC



>
>When phasing a pair of verticals a 1/2 wave apart and forcing equal currents
>by using two 3/4 wave 50 ohm coaxes to a T connector does it matter if RG8X
>for the 3/4 wave portions is used if the freq is 20 meters or is their too
>much loss, even on 20? I have Rg-214 but the 8X is so much easier to use.
>
>Lane
>Ku7i
>
>
>--
>FAQ on WWW:               http://www.contesting.com/towertalkfaq.html
>Submissions:              towertalk@contesting.com
>Administrative requests:  towertalk-REQUEST@contesting.com
>Problems:                 owner-towertalk@contesting.com
>Search:                   http://www.contesting.com/km9p/search.htm
>
>



--
FAQ on WWW:               http://www.contesting.com/towertalkfaq.html
Submissions:              towertalk@contesting.com
Administrative requests:  towertalk-REQUEST@contesting.com
Problems:                 owner-towertalk@contesting.com
Search:                   http://www.contesting.com/km9p/search.htm