Let's assume by "watts out" you mean watts forward.
SWR = 1 + SqRt(Pr/Pf) / 1 - SqRt(Pr/Pf)
For 100 watts forward and 10 watts reflected:
SWR = 1 +SqRt(10/100) / 1 - SqRt(10/100) = 1 + 0.31623 / 1 - 0.31623 = 1.31623
/ 0.68377 = 1.92
For 200 watts forward and 10 watts reflected:
SWR = 1 +SqRt(10/200) / 1 - SqRt(10/200) = 1 + 0.22361 / 1 - 0.22361 = 1.22361
/ 0.77639 = 1.58
Marsh, KA5M
-----Original Message-----
From: TowerTalk <towertalk-bounces@contesting.com> On Behalf Of k7lxc--- via
TowerTalk
Sent: Tuesday, August 14, 2018 11:19 AM
To: towertalk@contesting.com
Subject: [TowerTalk] Probably dumb question
If there are 100 watts out and 10 watts reflected, what's the swr?
If there are 200 watts out and 10 watts reflected, what's the swr?
Tnx.
Cheers,
Steve K7LXC