Topband
[Top] [All Lists]

Re: Topband: Ground Screens - Another Small Space Option

To: <zr@jeremy.mv.com>, topband <topband@contesting.com>
Subject: Re: Topband: Ground Screens - Another Small Space Option
From: Howard K2HK <k2hk@arrl.net>
Date: Tue, 25 Sep 2012 20:13:04 +0000
List-post: <topband@contesting.com">mailto:topband@contesting.com>
I didn't mean to imply that chicken wire is as good as the rabbit wire. In fact 
I had exactly that situation with chicken wire. Definitely agree that most 
situations must be evaluated on their own merits and circumstances. I am aware 
of Rob's call but just thought this might prompt him to relay some of his 
experiences.

Howard  K2HK


> From: zr@jeremy.mv.com
> To: k2hk@arrl.net; topband@contesting.com
> Subject: Re: Topband: Ground Screens - Another Small Space Option
> Date: Tue, 25 Sep 2012 15:11:26 -0400
> 
> Im sure chicken wire lasts longer in the great southwest but it rapidly 
> turns to rust in the acidic soil and acid rain of the New England rust belt. 
> I see rolls of it regularly at our trash transfer station and Id be willing 
> to bet the current Chinese variety rusts a lot faster than the earlier US 
> variety.
> 
> I keep stressing that the one size fits all theory of some just doesnt work 
> for Topband antennas and grounds.
> 
> It is not recommended to use stranded copper wire for RF or DC/AC grounds 
> and that should also apply to galvanized wire that only has a few twists at 
> each junction. Each junction can eventually become a diode and I believe 
> most of us on here are aware what that can cause.
> 
> Carl
> KM1H
> 

> 
> Rob Sherwood was once a strong advocate of chicken wire and has run many 
> tests. Perhaps he might chime in here with some comments.
> 
> 
> Howard  K2HK
> 
> 

                                          
_______________________________________________
UR RST IS ... ... ..9 QSB QSB - hw? BK

<Prev in Thread] Current Thread [Next in Thread>