I once fed a tower with a klm 40m beam with an insulated DE on it with and the
coax taped to the boom. The insulation on the coax broke down and the coax
caught fire. I grounded the DE. Problem solved.
John K9DX
> Date: Thu, 18 Dec 2014 05:43:06 -0600
> From: wa5rtg@gmail.com
> To: topband@contesting.com
> Subject: Topband: Shunt Feed - Insulated Elements on Yagi
>
> I have never had an issue with this on any tower I have shunt fed that had
> a Yagi at the top with insulated elements, but then again my insulators are
> probably a lot better than the average ones used on commerical antennas. I
> am thinking about shunt feeding a tower that is not mine and wanted to know
> whether anyone has had any issue runniing 1500 watts to a shunt fed tower
> that has a Yagi at the top with insulated elements. Im not wanting to
> ground elements and don't need additional top loading. What I would like
> to know is anyone has done any damage or melted anything.
>
> Thanks...Stan, K5GO
> _________________
> Topband Reflector Archives - http://www.contesting.com/_topband
_________________
Topband Reflector Archives - http://www.contesting.com/_topband
|