Topband
[Top] [All Lists]

Re: Topband: Help installing compression connectors

To: topband@contesting.com
Subject: Re: Topband: Help installing compression connectors
From: Phil Duff <na4m@suddenlink.net>
Date: Mon, 17 Nov 2014 15:06:04 +0000
List-post: <topband@contesting.com">mailto:topband@contesting.com>
There are different SNS F connectors. The SNS connectors will have different sleeve colors depending on application.

http://www.tnb.com/pubint/docs/snapnseal.pdf

I use the red sleeve connectors on flooded double shielded Commscope RG6. Using the recommended stripping and compression tool and fold the braid back and it goes on easily and fits fine.

73 Phil NA4M



On 11/17/2014 14:44, Tony K1AMF wrote:
Anyone have any suggestions on how to install compression connectors on flooded 
RG6 quad shield coax with PE jacket?   I'm using Belden Snap-N-Seal RG6QS 
compression connectors but they're nearly impossible to slip on far enough.  
I've tried removing the outer  braid and foil and still no luck.  Maybe I 
should be using different connectors?  The coax I'm using for the beverage is 
Commscope F6SSEF / 4561804.

--
Phil Duff
Georgetown, TX