On 4/21/2011 11:00 PM, John Langdon wrote:
> I think it is high ground conductivity that is often true of soil near the
> ocean, not the ocean per se.
>
> 73 John N5CQ
>
>
> 2/11
One thing you can do is remove the Beverage wire from you feed 
transformer and measure the return loop resistance with a VOM.  If the 
value you read is 100 ohms higher or more than your termination you are 
probably OK.  I have not heard this test suggested before but it may be 
worth passing on.