Stay away from the low priced RG-6. I used to buy 500 foot rolls of RG-6 Quad 
from Home Depot to be used to feed my beverages and K9AY loop.
 
The cable was made in Canada. Its weakness is its PVC jacket which is easily 
scored, nicked, or cut. I found several instances in my system where a small 
tear occurred and allowed water into the cable. The outside aluminum shield 
quickly deteriorates and a powder starts to form.
 
The best way to go is to use a flooded cable which I will do for all 
replacements. Also, once installed, it is a good idea to measure the total 
cable resistance of the installed feedline and record it for future reference 
and trouble-shooting. I was surprised at the resistance of the combined center 
conductor and shield of a 500 foot length of feedline. It runs in the range of 
14 to 18 ohms for RG-6.
 