TenTec
[Top] [All Lists]

Re: [TenTec] Pegasus Relays Found

To: tentec@contesting.com
Subject: Re: [TenTec] Pegasus Relays Found
From: Bob McGraw K4TAX <rmcgraw@blomand.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Tue, 23 Jun 2020 11:40:21 -0500
List-post: <mailto:tentec@contesting.com>
My Jupiter Parts list shows 14 pcs of H500F12-1-C as the relay used.

NTE R46-5D12-12 SPDT printed circuit 12 Volt DC relay

Equiv. To Potter Brumfield T7CS5D-12 & T7CV5D-12

The relays on the Low Pass filter board have the coils  wired in parallel for each band.  The individual coil resistance is 400 ohms.   Thus with 2 in parallel then the measured resistance should be about 200 ohms.  It is typical for the coil to open. Measuring the resistance will than allow one to determine the defective relays.   Usually the fault appears as no output or low output as associated with only 1 or 2 bands.

73

Bob, K4TAX


On 6/23/2020 11:20 AM, Mead, John S wrote:
For Pegasus and Jupiter users: I think I found the relays on the low-pass 
board. They are Hasco KLT1C6DC12 and are available at various parts outlets.
73,
John, W9OW