TenTec
[Top] [All Lists]

Re: [TenTec] Argosy 2

To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: Re: [TenTec] Argosy 2
From: Steve Hunt <steve@karinya.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Fri, 31 Aug 2018 10:24:19 +0100
List-post: <mailto:tentec@contesting.com>
The manual quotes 0.3uV for 10dB S/S+N typical - that would be-117dBm into a 50 Ohm load.

Is it the same on all bands?

Steve G3TXQ

On 30/08/2018 20:41, ROLAND HOWELL via TenTec wrote:
  Hi AllI have an ARGOSY 2 525D, it has a very lazy 'S' meter, requiring some -75dBm from my 
2022e to get it to move, it also seems a little deaf, I am not hearing the tone from the 
sig gen till its at -99dBm, don't know what it should be but most other rigs I have looked at 
are about -119dBm .The manual shows the original band pass filter board but mine has a 
board numbered 91696 for which I cant find and service diagrams.I want to repair this before 
moving it on, I have 2, + OMNI 6 PLUS, + Argonaut 509 and OMNI C ( 3 of) and 1 that I cant 
remember but it has a digital display with a faulty back light, which is not available any 
more. If there is a service document available can a kind person point me in the right 
direction.Thanks, Snowy G0HZE
_______________________________________________