| Remove the covers.  Loosen the top screws to the upper left and right sides 
to allow the front panel to tilt forward.  Un plug all the ribbon cables, 
one at a time, and re plug them.  I recall that the display board and 
display processor are mated with a sandwich connector.  Work these apart and 
re-assemble.  Put it all back together and likely the problem will be 
solved. 
73
Bob, K4TAX
----- Original Message ----- 
From: "John King" <k5pgw@yahoo.com> 
To: <tentec@contesting.com>
Sent: Wednesday, November 06, 2013 4:23 PM
Subject: [TenTec] Omni VI + KC digit
 I have a wonderful Omni VI+ transceiver, which I have used for many years, 
that functions beautifully EXCEPT for one digit in the digital readout that 
doesn't read. That is the kilocycle digit that doesn't read and shows 
nothing in the kilocycle range.
In other words, 3.925.00 reads 3.92-.00. The readout does not display the 
kilocycles for us OLD geizers or kilohertz for the baby boomers and newer 
Ten Tec fans. 
Has anyone experienced intermittent digit readout such as that described 
above? If so, what did you find wrong and how did you cure the problem? 
Your input will be appreciated based upon your Ten Tec knowledge and 
experience.And YES it is plugged in. 73, John, K5PGW 
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
 
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
 |