| Subject: | [TenTec] Topband: Making my tower disappear - results |
|---|---|
| From: | Tree <tree@juno.com> |
| Reply-to: | tentec@contesting.com |
| Date: | Tue, 15 Jul 2003 20:14:30 -0400 |
| List-post: | <mailto:tentec@contesting.com> |
In order to verify that my current maximum in the drop wire corresponds to minimum current at the base of the tower, I added a current meter at the very bottom of the tower. This allowed me to see a relative measurement of the current in the tower. It turns out the minimum current in the tower was pretty close to the maximum current in the wire. However, I found the setting for minimum tower current was slightly lower in capacitance than maximum drop wire current. |