TenTec
[Top] [All Lists]

Re: [TenTec] OMNI VI illness

To: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Subject: Re: [TenTec] OMNI VI illness
From: Jim Allen <jim.allen@longhornband.net>
Reply-to: Discussion of Ten-Tec Equipment <tentec@contesting.com>
Date: Sat, 25 Oct 2014 19:04:27 -0500
List-post: <tentec@contesting.com">mailto:tentec@contesting.com>
When I had this malady on 160 on my VI+, the factory replaced all the
relays on some board, about $350.00.  They also in that redid something to
bring the 30M output up to spec.

73 de W6OGC  Jim Allen

On Sat, Oct 25, 2014 at 6:41 PM, Dave Edwards <kd2e@comcast.net> wrote:

> Can anyone suggest if there is anything to check on this problem?
> OMNI VI+, otherwise working fine, but....
> No output on 15 or 17 meters.
> I can hear the signal on another receiver, but no output at all.
> Receive OK, and all other bands transmit fine.
>
> Is there something switched in for just 15 and 17?
>
> Thanks for any thoughts!
>
> ....Dave
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
>
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec