Check the 2 pin Molex connector on the radio. With multiple insertions
and the current draw, the tin contacts are noted to heat and loosen and
thus not make good contact with the cable contacts. Look for any
discoloring on either connector. If discoloring exists, replace both
male and female connectors.
I'd replace the original connector with PowerPole circuit board mounting
connectors and likewise, change the power cable connector. Also, be
sure the radio power cable is connected direct to the power supply and
not through a DC Distribution panel or strip.
73
Bob, K4TAX
On 9/26/2018 3:45 PM, W5SJL Amos Favorite wrote:
The Transceiver Went dark while receiving band activity
No S meter Lamp
No Led illuminated
No Display Light
No TX
No Rx
A very low sound when he power switch is set to on
Main Power Fuse is good
566 works fine on the power cable and Power Supply.
Electrolytic Caps on Power board are still ok
--------------------------------------------
Is there another reset?