That won't put you off frequency. Do you have a logging program that is communication with the Omni VII? If it is not using RTS/CTS handshaking, it can cause the Omni VII to have an XIT value. You have to power off the Omni VII and back on to clear this.

Carl Moreschi N4PY
58 Hogwood Rd
Louisburg, NC 27549
www.n4py.com

On 8/30/2018 12:17 PM, denton sprague wrote:
Hi all…I installed an if port output as per 3 rivers TT omni vii dongle 
instructions to enable me to use a pc as a spectrum monitor. it works fine on receive 
but the minute I transmit, am told I am off frequency.
I am thinking of either installing a relay that will disconnect the dongle’s if input 
during transmit…
Anyone else have a different work around?