On 4/29/2012 5:21 AM, David Perrin wrote:
> Can anyone redirect me to the location to pick off the i.f.? One side of the
> signal is ground which I have taken on the outside circuit trace around that
> area on the board.
Ground is not ground is not ground. There is considerable inductance
reactance at 9 MHz between where you're trying to pick up signal and the
chassis. The RIGHT way to do this to run coax between where you're
taking the signal to a chassis mounted connector, connecting the shield
to common on the circuit board close to where you've taken the signal.
Then run to the P3 from that chassis-mounted connector.
If you open up a Ten Tec amp, you will see exactly this technique for
both input and output.
73, Jim K9YC