Hello Alan & all,
I just got a message from the Ten-Tec support and they'll send me 2 new
capacities to replace C6 & C7 on the power distribution board (A9). It
seems that the problem with these capacities is recurrent and affects
many Orion's user...
73, Cedric HB9HFN
Date: 05.02.2008 15:37, Alan Sewell wrote :
Sounds like it could be the power distribution board. See this thread.
http://lists.contesting.com/_tentec/2007-11/msg00073.html
73,
Alan N5NA
http://www.tentecwiki.org
Cedric Baechler wrote:
Hello,
I have the following problem with my Orion II:
When I start it by using the switch on/off button the Ten-Tec logo
appears, then the normal screen (with frequency, sweep, ..) for a few
seconds then it reboots itself. This can happen 5-6 times until the
normal screen stays and the Orion is ready to use. Sometime during the
boot process and when the normal screen appears I see a single
horizontal white line on the screen!!
Before I contact Ten-Tec, has someone had this problem previously and
can help me?
73, Cedric HB9HFN
|