On Fri, 21 Dec 2007 19:39:34 -0600, Bob McGraw - K4TAX wrote:

>Since they all share the same neutral and ground there 
>are no ground loops or current differential issues.

Yes, this is an excellent technique, and I strongly recommend it. 

BTW -- the thing that is important is the having same SAFETY GROUND 
point, not the neutral. It is the AC voltage difference between the 
"green wires" at different outlets that causes shield current, resulting 
IR drop in the shield, and exciting pin 1 problems, both of which couple 
hum and buzz. 

73,

Jim Brown K9YC