On Mon, 2008-02-04 at 23:35 -0600, Stuart Rohre wrote:
> Thanks Bob!
>
> I would caution the poster to then, definitely NOT use the 15 volt power
> supply if it is unregulated without some precautions or additions.
>
> He might put a filament transformer in series to the line to the primary of
> the unregulated transformer to buck the output voltage down to a more
> reasonable 13 volts. If it was the typical Continuous Commercial Service
> rated supply, he might then be able to trust it staying near a normal
> voltage range for the rig.
Filament or buck/boost, the latter made for the job.
But it might be a Sola type regulator so that changing the line voltage may
not drop the voltage.
73, Jerry, K0CQ
>
> What do you think?
> 73,
> -Stuart
> K5KVH
>
>
> _______________________________________________
> TenTec mailing list
> TenTec@contesting.com
> http://lists.contesting.com/mailman/listinfo/tentec
_______________________________________________
TenTec mailing list
TenTec@contesting.com
http://lists.contesting.com/mailman/listinfo/tentec
|