To: | "Discussion of Ten-Tec Equipment" <tentec@contesting.com> |
---|---|
Subject: | Re: [TenTec] DX4WIN_O2_INTER_WORKING_FIXED |
From: | "George" <goofyham@highstream.net> |
Reply-to: | Discussion of Ten-Tec Equipment <tentec@contesting.com> |
Date: | Sat, 2 Sep 2006 19:48:34 -0400 |
List-post: | <mailto:tentec@contesting.com> |
I figured out what the problem was. It was the Radio Shack USB to DB9 adaptor feeding the O2/SteppIR Y cable. Apparently the USB port doesn't like the fact that there is nothing responding at the DB9 end. I switched my rotor, which is also DB9 to the USB adaptor and put the Orion2/SteppIR Y cable on a DB9 com port right off the computer. No more hang-ups. I do see another problem in that if you shut down your Orion the com port goes to sleep and will not wake up until DX4WIN is shut down and re-started. Thanks. George _______________________________________________ TenTec mailing list TenTec@contesting.com http://lists.contesting.com/mailman/listinfo/tentec |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [TenTec] FS: Ten Tec Orion II and accessories, NZ8J |
---|---|
Next by Date: | Re: [TenTec] FS: Ten Tec Orion II and accessories, Sinisa Hristov |
Previous by Thread: | Re: [TenTec] DX4WIN_O2_INTER_WORKING, Larry Menzel |
Next by Thread: | Re: [TenTec] DX4WIN_O2_INTER_WORKING, Duane Calvin |
Indexes: | [Date] [Thread] [Top] [All Lists] |