Steve,
I should have mentioned that the FCC limits to which a micro inverter is
subjected on the AC line side are only conducted limits.
Dennis AE6C
On Wed, Sep 2, 2020 at 7:17 PM Dennis Monticelli <
dennis.monticelli@gmail.com> wrote:
> Steve,
>
> Yes, per panel electronics could be of either type, DC to DC (optimizer)
> or DC to AC (micro inverter). When it comes to RFI generation there is
> more potential for it from the DC to DC type. This is because there are no
> explicit FCC limits placed upon the connection between the optimizers and
> the central inverter and those runs can be long. However, a micro inverter
> must connect to the AC mains so at least with that type there are some FCC
> limits with which to adhere on the AC side.
>
> Dennis AE6C
>