On 3/28/2013 9:52 AM, David C. Cole wrote:
1. Make sure all splitters have termination on unused ports.
2. Make sure all items are grounded as per code.
3. Make sure all cable connections are tight as can be.
Of these, I would place the greatest emphasis on #3. With respect to
#2, the real issues are
Termination of the cable shield at each end to the shielding enclosure,
NOT directly to the circuit board;
and
bonding together of all grounds within the premises by short, fat
copper. That includes, but is not limited to, telco, CATV, satellite,
power, ham antennas, and lightning protection.
I see no relevance to his #1 with respect to RFI. The real issues are
his #3 and the cable shield issue (The Pin One Problem), both of which
are well known causes of both ingress and egress with systems of all sorts.
73, Jim K9YC
_______________________________________________
RFI mailing list
RFI@contesting.com