Well I just shot my entire Saturday working around a little Karlnet 4.45
bug.
Here is the setup that DIDN'T work:
TOWER #1
--------------
KN100 with 4.45 AP+ SEC with 200mw PRISM card
TOWER #2 (connects to tower #1)
-------------
RG1000 with 4.45 SEC Client with Unlimited Bridging with 35mw ORINOCO card
RG1000 with 4.45 AP+ SEC with 35mw ORINOCO card
The RG1000 client will connect to the KN100 and will respond to pings, but
it won't bridge/router or NAT to the RG1000 AP+.
The workaround involved installing a new RG1000 AP+ SEC running 4.45 and a
35mw card at tower #1. So, it seems that the RG1000 SEC Client would only
work when talking 35mw to 35mw. Anyway... Karlnet...HELP! I'm sure this
isn't the last time this bug causes us problems.
Thanks,
Larry Yunker
Cyber Broadcasting, L.L.C.
---
[This E-mail scanned for viruses by Cyber Broadcasting's Declude AntiVirus]