To: | "Karlnet Mailing List" <karlnet@WISPNotes.com> |
---|---|
Subject: | Re: [Karlnet] Lockups KN205 |
From: | "Steve Loomis" <loomiss@cox.net> |
Reply-to: | Karlnet Mailing List <karlnet@WISPNotes.com> |
Date: | Thu, 16 Dec 2004 17:12:16 -0600 |
List-post: | <mailto:karlnet@WISPNotes.com> |
We had that problem for a while, but raised the POE voltage to the point
where we were getting at least 12 to 15 volts at the end of a 100' Cat 5
run. We can go months and months without a reset or lockup. We have other
KN205's on short cat5 runs or direct power plug in and have had NO problems
with them. Before we got them upgraded from KN200's we had lots of
problems, not now...Steve Loomis vroomwireless.com ----- Original Message ----- From: "Alex Phillips" <alexp@rbns.net> To: "'Karlnet Mailing List'" <karlnet@WISPNotes.com> Sent: Thursday, December 16, 2004 5:02 PM Subject: RE: [Karlnet] Lockups KN205 I have that problem about 1 a month. I am going to upgrade to 4.46 to see if that helps.
|