I did a similar mod on my AL-1200. If you read the original QST review
you will note that some of the early ones had incorrectly wound HV
transformers - mine must have been one of those, as it never got over
3200V. I added one filter cap and bleeder to bump the rating of the
capacitor bank to 9x450=4050V, then changed the primary tap on the
transformer. I now get 3600V on the HV. This gets the output and gain up
where it should be.
It has run this way for a decade. -Tony, K1KP _______________________________________________ CQ-Contest mailing list CQ-Contest@contesting.com http://lists.contesting.com/mailman/listinfo/cq-contest |