Can you file a complaint with eBay and get your $$ back? Sounds like the
"RG400" is actually not-as-advertised.
73, ron w3wn
-----Original Message-----
From: CQ-Contest [mailto:cq-contest-bounces@contesting.com] On Behalf Of N4ZR
Sent: Wednesday, March 13, 2019 9:51 AM
To: Wayne Kline; charlie carroll; cq-contest@contesting.com
Subject: Re: [CQ-Contest] Station Re-Build - Coax
I just bought 10 feet of RG-400U (supposedly Harbour Industries) through
E-bay for $13. Belatedly, I learned it was coming from China. It's now
here, but I don't think it is for real - it only has one shield, and is
somewhat stiff. At least the inner conductor isn't magnetic.There's no
printing on the cable.
Buyer beware.
73, Pete N4ZR
Check out the Reverse Beacon Network
at <http://reversebeacon.net>, now
spotting RTTY activity worldwide.
For spots, please use your favorite
"retail" DX cluster.
On 3/12/2019 11:35 PM, Wayne Kline wrote:
> I third the sugjestion of the RG400 small enough for all the switching
> in a more then one radio setup.
>
> The tight bend radius the small diameter make for a clean instlation that
> coupled with the double shielding it’s a WIN WIN
>
> Watch Ebay or other surplus suppliers
>
>
>
> Wayne W3EA
>
>
>
> Sent from Mail<https://go.microsoft.com/fwlink/?LinkId=550986> for Windows 10
>
>
>
> ________________________________
> From: CQ-Contest <cq-contest-bounces@contesting.com> on behalf of charlie
> carroll <k1xx@k1xx.com>
> Sent: Tuesday, March 12, 2019 10:23:06 PM
> To: cq-contest@contesting.com
> Subject: Re: [CQ-Contest] Station Re-Build - Coax
>
> Keith:
> A couple very similar candidate cables are RG-400 and RG-303. RG-400 is
> double shielded while 303 is single. They're good as interconnects
> because they have a small bend radius (about 1"). RG-400 uses
> multi-strands of copper for the center conductor; RG-300 uses copper
> clad steel. Either will handle 1500 watts at HF.
>
> 73 charlie, k1xx
>
> On 3/12/2019 7:51 PM, Keith Dutson wrote:
>> My multi-two station, with third spotting station, is being rebuilt into new
>> digs. I have a lot of 3-4 foot RG213 cables running between the amp, power
>> meter, tuner and switch. I have heard there may be a smaller cable that has
>> very little loss, but handles 1500 watts. I would appreciate any comments
>> on what is being used today. Thanks.
>>
>> 73, Keith NM5G
>> _______________________________________________
>> CQ-Contest mailing list
>> CQ-Contest@contesting.com
>> http://lists.contesting.com/mailman/listinfo/cq-contest
>>
> _______________________________________________
> CQ-Contest mailing list
> CQ-Contest@contesting.com
> http://lists.contesting.com/mailman/listinfo/cq-contest
> _______________________________________________
> CQ-Contest mailing list
> CQ-Contest@contesting.com
> http://lists.contesting.com/mailman/listinfo/cq-contest
>
_______________________________________________
CQ-Contest mailing list
CQ-Contest@contesting.com
http://lists.contesting.com/mailman/listinfo/cq-contest
---
This email has been checked for viruses by Avast antivirus software.
https://www.avast.com/antivirus
_______________________________________________
CQ-Contest mailing list
CQ-Contest@contesting.com