Amps
[Top] [All Lists]

[Amps] Grid Meter

To: amps@contesting.com
Subject: [Amps] Grid Meter
From: JMLTINC@aol.com
Date: Sun, 19 Nov 2006 13:46:18 EST
List-post: <mailto:amps@contesting.com>
 Thanks, Lou. First thing I did - the shunt is OK.

I should add that power on either tubes is down, with max at 1,500 Watts into 
a DL. Plate current at full power is about 800ma @ about 4500 volts. Idling 
current about 100ma, with bias measured at CT of fil x-former at about 13 volts.

In a message dated 11/19/2006 11:10:43 A.M. Eastern Standard Time,  
JMLTINC@aol.com writes:

My  problem is: when the amp is keyed (no drive) the grid meter slams forward 
 
against the peg. Does this with two tubes. Disconnect the filament leads  and 
it does not budge.




Check to see if your grid shunt resistor/s on the grid meter are  opened.  Lou
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps