If the amp was stored in damp conditions it is possible that moisture
may be the culprit. You could try baking the choke in a low oven for a
good period of time (?). That would be sure to expel any moisture.
Failing that and with a rewind or replacement not possible then
insulating it well from ground might be a reasonable work around. I
would however be sure to label clearly inside the psu compartment what
you have done. You might well remember but who knows where it ends up in
the future. I have a friend who did that with the plate transformer in a
Henry and it worked well.
You can use paxolin, perspex, pretty much anything you can get I guess
but do label it!
73
Martin, HS0ZED
On 27/09/2019 09:07, jeff millar wrote:
Hello wise ones...
Bought a nice 3K-A at a flea market and made one SSB contact. On the
second contact it tripped off on HV overcurrent. After some debugging, the
Plate choke is leaky to ground at HV but open with an Ohm meter.
Can I just put the choke up on insulated standoffs?
Any other suggestions?
thanks,
jeff, wa1hco