To: | n7ioh <n7ioh@cybertrails.com> |
---|---|
Subject: | Re: [Amps] 4-1000A in Passive grid-driven use? |
From: | R.Measures <r@somis.org> |
Date: | Wed, 28 Apr 2004 20:39:43 -0700 |
List-post: | <mailto:amps@contesting.com> |
On Apr 28, 2004, at 12:38 PM, n7ioh wrote: Are there any problems in using the 4-1000A in a passive grid-driven mode on 160 - 10 meter or on 6 meters? Above 30m, it's a good idea to tune out the grid's XC. See: http://www.somis.org/D_a_05.GIF The XL of L1 tunes out the grid's XC for whatever frequency you choose. note -- this is the first step in tuning up such a machine. . If not, what kind of output can I expect to get? Depends on anode V and screen V. With 7kV and 1kV, you should be able to get 2.6 out. Second, I have seen amps that use a roller inductor and not a band switch, any thoughts? They provide the best match over a wide frequency range. Richard L. Measures, AG6K, 805.386.3734. www.somis.org _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [Amps] mega mobile, R . Measures |
---|---|
Next by Date: | Re: [Amps] 4-1000A in Passive grid-driven use?, Traian |
Previous by Thread: | [Amps] 4-1000A in Passive grid-driven use?, n7ioh |
Next by Thread: | Re: [Amps] 4-1000A in Passive grid-driven use?, Traian |