On Sep 17, 2004, at 8:26 AM, jsb@digistar.com wrote:
On Thu, 16 Sep 2004, R.Measures wrote:
the choke for the 3-500Zs would need to be wound with #8 gauge wire.
I have been reading with interest about the filament chokes for 3-500Z,
etc. In the photos I've seen of projects the filament choke appears
to be
bare wires around the ferrite rod. Am I seeing this correctly?
Jason --- The Cu wire is insulated with a plastic coating. Modern
electric-motor and transformer wire is insulated with silicone varnish.
This insulation is so tough that is is usually burned off with a
propane torch and the ash thereof is removed with steel-wool.
Richard L. Measures, AG6K, 805.386.3734. www.somis.org