| Carsten ----------  I would start by testing the tube separately with a 
high-potential tester.  This will isolate the problem to either the 
amplifier or the electron tube. 
 On Nov 5, 2004, at 5:01 AM, Carsten Esch wrote:
 
 
 ... one of my 2000A amps just switched off indicating IG2=011mA SHOULD 
BEZERO. Whats wrong? Any idea where to look first?
 
 Thanks!
 
 Carsten, DL6LAU
 
 
 _______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps 
 
 Richard L. Measures, AG6K, 805.386.3734.  www.somis.org
 
 
 _______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps 
 |