Amps
[Top] [All Lists]

Re: [Amps] Alpha 86

To: "gudguyham@aol.com" <gudguyham@aol.com>
Subject: Re: [Amps] Alpha 86
From: c miller <c_miller_1@hotmail.com>
Date: Tue, 8 Nov 2022 21:52:29 +0000
List-post: <mailto:amps@contesting.com>
Not too odd really.  On 120v it is possible to run the initial startup cycle on 
just one of the two windings.  Then once the soft start circuit bypasses then 
both windings come into operation and unit preforms as intended.  However, with 
either fuse F3 or F4, or resistor R6 or R7, in the soft start circuit being 
open, no power ever gets passed on to the transformer thus locking the rig in a 
power off state.  The relay k11 (click) is the only part that is able to 
operate in that failure mode

Chris
VE3CEA 


Sent from my iPhone

> On Nov 8, 2022, at 16:31, gudguyham--- via Amps <amps@contesting.com> wrote:
> 
> It’s odd that it works on 120 and not 240.  I looked in the manual but the 
> terminal strip is not numbered on the schematic.
> 
> 
> Sent from the all new AOL app for iOS
> 
> 
> On Tuesday, November 8, 2022, 3:24 PM, David Tenenbaum <dmt013@gmail.com> 
> wrote:
> 
> Thanks for the feedback!
> I am still on the clock at work but took a break to check R8 and I am seeing 
> 3.98K ohms, so the 4k resistor seems intact. Later tonight when finally done 
> with work I will tear into it to look at the fuses and other resistors, 
> confirm there is REALLY 220 v getting to the unit, and anything else that 
> comes up.
> Thanks all for the ideas!!!!
> David N1RO/VE3TMK
> 
> 
> On Nov 8, 2022, at 2:33 PM, gudguyham@aol.com wrote:
> Did you check R8 for open?
> 
> 
> Sent from the all new AOL app for iOS
> 
> 
> On Tuesday, November 8, 2022, 2:20 PM, David Tenenbaum <dmt013@gmail.com> 
> wrote:
> 
> Hi All,
> 
> I have an Alpha 86 that I have been using set up for 110v, and finally have 
> access to 220v, so looking forward to seeing what it can REALLY put out. 
> Unfortunately I have made the jumper changes (terminal in the back for 110 
> operation has locations 1&2 jumpered, 3&4 jumpered, and 5&6 jumpered, but for 
> 220 only locations 2&3 are jumpered), and the unit fails to light up or come 
> online. I hear a single relay activation when I hit the "On" switch, but no 
> lights or fan.
> 
> Fearing I hurt the unit I restored it to 110v operation and all is good. I 
> set it back to 220v and same problem. I checked continuity from the plug's 
> ground to chassis ground, and the hot leads show continuity to the right 
> places. I have been using a 220v SB200 on that outlet just fine.
> 
> Any thoughts or leads appreciated! Never thought I would have a problem just 
> switching supply voltages.....Scan of schematic attached....
> 
> Best,
> 
> David
> N1RO/VE3TMK 
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
> 
> 
> 
> 
> 
> 
> 
> 
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
<Prev in Thread] Current Thread [Next in Thread>