Amps
[Top] [All Lists]

Re: [Amps] toroid tank coil heating up

To: John Keating <john.keating@outlook.com>
Subject: Re: [Amps] toroid tank coil heating up
From: Gary Schafer <garyschafer@largeriver.net>
Date: Sun, 26 Sep 2021 12:27:23 -0500
List-post: <mailto:amps@contesting.com>
If the winding has taps for 80 and 40 and the taps get shorted with the band 
switch, then that is the problem.
You should use separate cores for each band.
If you were to leave the taps open then you may have arcing problems.


Sent from my iPhone

> On Sep 26, 2021, at 10:54 AM, John Keating <john.keating@outlook.com> wrote:
> 
> My 2 x 3-500Z amp uses a two-stack T-225A-2 red mix iron powder toroid for 
> 160-80-40. It gets hot, especially on 160, changing the loading and causing 
> the grid current to drift up on extended transmission. This is not a new 
> phenomenon, but I thought I would ask the experts if there is a remedy, 
> perhaps other than using a triple stack or going to an air core coil, neither 
> of which I have room for.
> 
> John
> AI6LY
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps

_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
<Prev in Thread] Current Thread [Next in Thread>