On Mon, 04 May 2015 08:09:47 +0800, you wrote:

>Might I be allowed to suggest that Accuracy +/- 5% of Full Scale Power" 
>means that the best accuracy they guarantee is that 5% at full scale.
>
>At lower readings, it may still be 5% or it might be a little more. 
>Whatever the figure might be, to cover their ass, the manufacturer is 
>not going to make any guarantees other than at full scale.
>
>To suggest +/- 125 Watts anywhere on the scale, for a 2500 Watt range,  
>simply does not make sense and it would make a total mockery of the 
>using the instrument as a power measuring device.
>
>73, Alek.
>VK6APK

REPLY:

Perfectly stated. Thank you, Alek.

73, Bill W6WRT



##  Nice try Bill...it doesn’t work that way.   Its +/- 5%  of full 
scale.....anywhere on the scale.   Even W8JI harps
on upon that fact.   If you try and measure  say 100 watts..using a 2.5 kw 
slug, you will get BS readings.   You need to use
the smallest element that will do the job.   That’s why I have elements for 
100-250-500-1000-2500-5000-10,000 and 25 kw. 

##  from birds site...from the Bird Q+A  url the fellow posted..which u 
obviously didn’t read. 
      Question / Issue 
     
      Bird 43 wattmeter with 250H slug element. Does the 5% +/- accuracy at 
full scale mean it also has the same 5% accuracy at any point along that scale, 
or is it more accurate for levels below 250w?  I believe you understand my 
question. Thanks! 

      Answer / Solution 
     
      With the Bird 43 the +/- 5% accuracy full scale means at 250 watts the 
accuracy is based on the 250 W element in use. So using a 250W element the 
accuracy is 250 watts + 5% and 250 watts -5%, or 250 +12.5 watts or 250 -12.5 
watts. The accuracy window is therefore 237.5 to 262.5 watts.

      If you try to measure 200 watts using the 250 watt element then the SAME 
+12.5 or -12.5 accuracy window is still in effect, as it is BASED ON FULL SCALE 
OF THE ELEMENT. 

      If you need the accuracy to track the lower power then the accuracy spec 
you need to look for is +/- 5% of display. We also manufacture that type of 
metering.



      ##  Note, in my experience, if you use an element that is too big for the 
job, the results  will be on the high side..but not by a helluva lot.  Bird sez 
to use the smallest slug to do the job.   My L4B in low power mode indicates 
700 watts..using a 5 kw slug. It indicates 650w, using a 2.5 kw slug.    It 
indicates 625 watts..when using a 1 kw slug.   The 625 result is close to dead 
on.   Some of it will depend on what freq you are on.  The elements cover 2-30 
mhz... and I still don’t know what freq they are calibrated at...when they 
leave the factory.   They read BS on 160m too...way too high.   They make a 500 
khz to 2.2 mhz slug that may be a bit more accurate on 160m.   Also, the 
readings will drift to the high side when the room temp is higher.   IE:  60 
deg F in the morning..vs  85 deg F  in the late afternoon.     The array 
solutions power master meters are not affected by room temp.   Array solutions 
sez they hand calibrate each coupler to NIST standards.  If you want to 
calibrate it urself, go for it.  The frwd and rvs calibration points can be 
tweaked in 1% increments...from  -15%  to  +15%.   They mark the calibration 
settings to use on each coupler....once for 160-10m...and again for 6m band.   
Worse case scenario is if a 1% calibration point straddled  the actual real 
power.   In which case the most it can be off is .5%. 

      ##  1.5 kw is  5.477  amps into a 50 ohm load.  = 273.861 volts rms.   = 
387.2398 V peak.   =  774.4797 peak to peak.    Its not rocket science to 
calibrate a scope to read 387.2398 volts.   IE: make sure a real 400V Peak 
indicates 400 V peak on the scope.   As noted b4, if the scope is off by just 
1%..the calculated power results will be off by 2%...or double.   Since power = 
V squared / 50 ohms.  

      ##  Everybody that I know that uses an AL-1500  / Om etc, etc,  brags how 
they run em at 2.5 kw pep out on 80m.  That has been going on for years.  Ok, 
so they are 2.2 db more than 1.5 kw...who really cares.  Measuring po at the 
back of the amp is silly anyway.   What really counts is ERP...which will be a 
function of feed line loss  plus gain of the ant plus po of the amp.  1.5 kw 
into a stacked array is...ok, meanwhile 1.6 kw into a dipole is a no-no...gimme 
a break. 

      Jim   VE7RF     
     