First guess would be severely pitted relay contacts.
Carl
KM1H
----- Original Message -----
From: "Dr. G. Carl" <dtruss327@aol.com>
To: <amps@contesting.com>
Sent: Friday, February 03, 2012 4:05 PM
Subject: [Amps] NEED HELP WITH FL 2100B
> NO OUTPUT, NEW TUBES INSTALLED. WHEN RELAY CLOSES IN OPER POSITION, DRAWS
> ABOUT 50-100ma only. POWER METER SHOWS
> no OUTPUT, ALSO, STRAIGHT THROUGH WITH POWER OFF, EXCITER HAS LITTLE TO NO
> OUTPUT INDICATED ON POWER METER.
>
> ANY SUGGESTIONS BEFORE I DIG IN TO IT.
> DR. G. CARL W7BQ
> _______________________________________________
> Amps mailing list
> Amps@contesting.com
> http://lists.contesting.com/mailman/listinfo/amps
>
>
> -----
> No virus found in this message.
> Checked by AVG - www.avg.com
> Version: 10.0.1424 / Virus Database: 2112/4783 - Release Date: 02/03/12
>