Yes if you rectify it (a use for those old 1B3, 3A3 tubes) and use a very small
cap (.001 or mf or less) as a filter sure. Remember to current limit the
output so you do not cause damage due to flashover and protect your analog
meter with 2 diodes across the terminals. For a filament supply you can use a
"D" cell for short term use.
Randy E. Randall AB9GO
Network Engineer
UC Health
Randy.Randall@UCHealth.com
Phone 513-585-7146
Fax 513-585-7159
-----Original Message-----
From: amps-bounces@contesting.com [mailto:amps-bounces@contesting.com] On
Behalf Of Mike
Sent: Sunday, July 15, 2012 11:29 PM
To: amps@contesting.com
Subject: [Amps] Neon xfmr for HiPot
Hello,
Can a 10 KV, 30 mA., xfmr used for a neon light be used in a hipot tester?
Seems like a natural with just a small variac used to vary the primary voltage
(120 VAC) for adjusting the output voltage.
73,
Mike, K4GMH
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps