To: | Amps reflector <amps@contesting.com> |
---|---|
Subject: | [Amps] TL-922 loading capacitor |
From: | Vic K2VCO <k2vco.vic@gmail.com> |
Date: | Sat, 08 Oct 2011 07:56:45 -0700 |
List-post: | <amps@contesting.com">mailto:amps@contesting.com> |
The TL-922 loading capacitor 'wants' to be at more than maximum capacity at the low end of 160 and 80m. Has anyone added additional capacity, and if so, how much? I'm thinking of adding a 500 pf "flying saucer" like the other ones in there. The amount of capacity (2920 and 1920 pf, respectively) looks reasonable, so it seems that they skimped on the inductance. -- Vic, K2VCO Fresno CA http://www.qsl.net/k2vco/ _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | [Amps] Alpha 77dx issue, Carcia, Joe, NJ1Q |
---|---|
Next by Date: | Re: [Amps] Converted '1200 [GS-35B] Output.., Carl |
Previous by Thread: | [Amps] Alpha 77dx issue, Carcia, Joe, NJ1Q |
Next by Thread: | Re: [Amps] TL-922 loading capacitor, Carl |