To: | Amps reflector <amps@contesting.com> |
---|---|
Subject: | Re: [Amps] SB-200 plate voltage under load |
From: | Vic K2VCO <vic@rakefet.com> |
Date: | Sat, 24 Jul 2010 15:04:56 -0700 |
List-post: | <amps@contesting.com">mailto:amps@contesting.com> |
On 7/24/2010 12:39 PM, Carl wrote: > 1900-2100 depending on 120/240 fed and actual line voltage. Thanks. That agrees with the PSU Designer program. I'm using an SB-200 transformer and just a bit more capacity in the supply for my 813 amplifier. I wanted to get a sanity check before cutting the pi net coils. -- Vic, K2VCO Fresno CA http://www.qsl.net/k2vco/ _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |