| To: | amps@contesting.com |
|---|---|
| Subject: | Re: [Amps] B&W FC-30 Filament Choke: EPILOGUE |
| From: | Steve Thompson <g8gsq@eltac.co.uk> |
| Date: | Sun, 04 Mar 2007 14:43:10 +0000 |
| List-post: | <mailto:amps@contesting.com> |
EP Swynar wrote:> > Now, on the MINUS side: > > -The FC-30 is specified for operation from 3.5-MHz to 30-MHz, inclusive: > because each FC-15 rod is only 3-1/2" long, it does not have enough > inductance for 160-meters; Assuming you're running connected as a grounded grid triode, the choke will appear as a shunt inductance to ground - can you simply choose the right capacitor to tune it to parallel resonance on 160m? Steve _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
| <Prev in Thread] | Current Thread | [Next in Thread> |
|---|---|---|
| ||
| Previous by Date: | Re: [Amps] B&W FC-30 Filament Choke: EPILOGUE, TexasRF |
|---|---|
| Next by Date: | Re: [Amps] B&W FC-30 Filament Choke: EPILOGUE, Gary Schafer |
| Previous by Thread: | Re: [Amps] B&W FC-30 Filament Choke: EPILOGUE, Dan Hearn |
| Next by Thread: | Re: [Amps] B&W FC-30 Filament Choke: EPILOGUE, Gary Schafer |
| Indexes: | [Date] [Thread] [Top] [All Lists] |