The MOT I used in my tester (<http://tester.gs35b.com>) has welds across
the laminations in four different locations. The transformer gets pretty
hot with no load (shunts removed). Fortunately, my duty cycle on the
tester is very low so it really doesn't matter for this application. The
four lines of weld is why I asked the question.
73, Tony W4ZT
John Popelish wrote:
> Tony King - W4ZT wrote:
>> Will,
>>
>> Do you think that the welded laminations will not be a problem and
>> increase losses? Beyond that, what you're saying is good news.
>
> Normally, they are quite careful about connecting the laminations
> along only one side of a possible eddy current loop. So it makes
> little difference in the lamination loss.
>
> (Sorry about the email, Tony. This service does not put the correct
> address in the reply to field.)