To: | amps@contesting.com |
---|---|
Subject: | Re: [Amps] QSK for TL-922 |
From: | bb <bbolin@yadtel.net> |
Date: | Thu, 28 Oct 2004 02:02:44 -0400 |
List-post: | <mailto:amps@contesting.com> |
Richard, I was wondering has anyone tried hitting the relay 2 or 3 times the coil voltage? The equipment I work with, to get faster times on air valves we take a circuit and hit the coil with a little over 3 times the coil voltage for 7-10ms and then ramp the voltage down to about 1/2 of the coil voltage for holding. Not sure if the mechanical parts of the vacuum relay can hold up to this never had one apart it may be worth testing. Just a thought. Bennie _______________________________________________ Amps mailing list Amps@contesting.com http://lists.contesting.com/mailman/listinfo/amps |
<Prev in Thread] | Current Thread | [Next in Thread> |
---|---|---|
|
Previous by Date: | Re: [Amps] Amazing ebay auction., Will Matney |
---|---|
Next by Date: | Re: [Amps] Amazing ebay auction., Tony King |
Previous by Thread: | Re: [Amps] QSK for TL-922, R . Measures |
Next by Thread: | Re: [Amps] QSK for TL-922 - correction, Will Matney |