There are 1ma movements with about a resistance of around 30 or so ohms. Full
scale voltage is around 30mv. You can reshunt any meter to make it work.
Sent from the all new AOL app for iOS
On Tuesday, October 31, 2023, 9:02 PM, wb0gaz via Amps <amps@contesting.com>
wrote:
Are the panel meters (plate current, and grid current/HV) considered a milli-
or micro-amp meter or a voltmeter? No info in the manuals. They are (per the
schematic) both effectively across sub-ohm shunt resistors (grid current is
across the sub-ohm shunt resistor to ground; plate current is across the
next-up sub-ohm resistor towards the HV PS negative terminal.)
Thanks for any suggestion/info
Dave
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|