On 7/25/06 at 2:20 PM R L Measures wrote:
>On Jul 25, 2006, at 11:51 AM, Will Matney wrote:
>
>> Peter,
>>
>> Thanks! That is the very point I have been trying to get across all
>> along! Remember, the original threads were asking about a 3-500Z
>> with the grid resistor or fuse in G-G., or it was when I jumped in
>> the mix There's been a lot of other tubes and circuits dragged into
>> the discussion, but I've tried to center my comments around a
>> 3-500Z G-G circuit. In grid driven circuits though as in receivers
>> and transmitters, or some amps, the grid can be made to go positive
>> for part of a cycle.
>
>If it does, there's a feculence flood. However, the 4cx600J and
>4cx1500B are fairly clean with up to 0.5mA of grid-I.
Agreed.
>
>> This I think Rich means also. He can correct me if I'm wrong.
>>
>> Thanks,
>>
>> Will
>>
>>
>> *********** REPLY SEPARATOR ***********
>>
>> On 7/25/06 at 8:40 PM Peter Voelpel wrote:
>>
>>> Hi Will,
>>>
>>> when the grid is kept grounded it can not become more positive
>>> then the
>>> cathode if that is grounded and not negative biased as well,
>>> except by RF
>>> drive on it above its choke.
>>>
>>> 73
>>> Peter
>>>
>>> -----Original Message-----
>>> From: amps-bounces@contesting.com [mailto:amps-
>>> bounces@contesting.com] On
>>> Behalf Of Will Matney
>>>
>>> Peter,
>>>
>>> On that, I agree it's the only way to make one positive (for only
>>> part of a
>>> cycle). Are there any other ways to make the grid positive and the
>>> grid be
>>> at ground potential with the cathode at ground? A lot of amps
>>> cathodes are
>>> at ground potential unless biased.
>>>
>>> Best,
>>>
>>> Will
>>>
>>>
>>>
>>> *********** REPLY SEPARATOR ***********
>>>
>>> On 7/25/06 at 8:04 PM Peter Voelpel wrote:
>>>
>>>> Nothing is easier then that if the cathode is going/driven
>>>> negative with
>>>> respect to ground.
>>>> Grid voltage is always measured from grid to cathode, not to ground.
>>>>
>>>> 73
>>>> Peter
>>>>
>>>>
>>>> -----Original Message-----
>>>> From: amps-bounces@contesting.com [mailto:amps-
>>>> bounces@contesting.com] On
>>>> Behalf Of Will Matney
>>>>
>>>> please explain how a grid becomes positive when tied to ground?
>>>>
>>>>
>>>>
>>>> _______________________________________________
>>>> Amps mailing list
>>>> Amps@contesting.com
>>>> http://lists.contesting.com/mailman/listinfo/amps
>>>
>>>
>>>
>>> _______________________________________________
>>> Amps mailing list
>>> Amps@contesting.com
>>> http://lists.contesting.com/mailman/listinfo/amps
>>>
>>> _______________________________________________
>>> Amps mailing list
>>> Amps@contesting.com
>>> http://lists.contesting.com/mailman/listinfo/amps
>>
>>
>>
>> _______________________________________________
>> Amps mailing list
>> Amps@contesting.com
>> http://lists.contesting.com/mailman/listinfo/amps
>>
>
>R L MEASURES, AG6K. 805-386-3734
>r@somis.org
_______________________________________________
Amps mailing list
Amps@contesting.com
http://lists.contesting.com/mailman/listinfo/amps
|