>With some socket, also the actual method to ground grid is prone to
>have inductance,
Amen, Mauri. 1-inch strap has around 12nH per linear inch.
>and inductive reactance yes increases with frequency.
>With proper bypassing capacitors and short leads, like with mica
>multistrate caps, one can aspect that loss (if any) and not reactance
>increase with frequency.
>
ciao, Mauri
>
>
>
>
>>
>> Presumably any bypass caps become more reactive with increasing
>> frequency, rendering the bypassing less effective anyway.
>>
>> Ian ZS6BTE
>>
>
>
>
>--
>FAQ on WWW: http://www.contesting.com/FAQ/amps
>Submissions: amps@contesting.com
>Administrative requests: amps-REQUEST@contesting.com
>Problems: owner-amps@contesting.com
>
>
- Rich..., 805.386.3734, www.vcnet.com/measures.
end
--