[AMPS] Re: The Worldwide, No Holds Barred, SWR Quiz.

To: <amps@contesting.com>
Subject: [AMPS] Re: The Worldwide, No Holds Barred, SWR Quiz.
From: measures@vcnet.com (measures)
Date: Mon, 4 Oct 1999 20:39:05 -0700
The tentative,, maybe ok, maybe not, answers.  

>Questions 1 and 2:  
>
>A 50-ohm termination is connected to a generator through a one-half 
>wavelength, 93 ohm characteristic-Z  coaxial cable.  
>
>What is the SWR as measured at the generator with a 50-ohm 
>characteristic-Z  SWR meter?  

? At the end of an any characteristic.-Z halfwave transmission line, the 
termination Z repeats itself --  with a reactance reversal.  .  Since 
there is no reactance in this termination, the Z at the end of the 93-ohm 
halfwave line is 50 +/- j0 ohms, the SWR is 1:1.  
>
>What is the SWR with a 93-ohm characteristic-Z  SWR meter?
>
?  93/50 = 1.86:1.  

How did I do? 

-----------
Question 3:

In Question 1, if the SWR meter were moved from the 1/2 wave point to the 
1/4 wave point, what would the SWR reading be?.  




-  Rich..., 805.386.3734, www.vcnet.com/measures.  


--