>the rf safety choke is there for a definite safety reason---to blow from the
>dc supply gitting thru the plate blocking cap--check it--bet it shorted.
>new call w5set.
When the DC blocker fails without a "safety choke" being present, the
Load C itself acts as a protective spark gap, arcs, and shorts the HV to
ground.
>73 de KB5VCA Steve & Darlene
>
>
>--
>FAQ on WWW: http://www.contesting.com/ampsfaq.html
>Submissions: amps@contesting.com
>Administrative requests: amps-REQUEST@contesting.com
>Problems: owner-amps@contesting.com
>Search: http://www.contesting.com/km9p/search.htm
>
-
- Rich...
R. Measures, 805-386-3734, AG6K, www.vcnet.com/measures
--