Amps
[Top] [All Lists]

[AMPS] Re:(AMPS) sb-200 troubles

To: <amps@contesting.com>
Subject: [AMPS] Re:(AMPS) sb-200 troubles
From: measures@vcnet.com (Rich Measures)
Date: Wed, 11 Aug 1999 09:01:14 -0700


>
>the rf safety choke is there for a definite safety reason---to blow from the
>dc supply gitting thru the plate blocking cap--check it--bet it shorted.
>new call w5set.

When the DC blocker fails without a "safety choke" being present, the 
Load C itself acts as a protective spark gap, arcs,  and shorts the HV to 
ground.  

>73 de KB5VCA    Steve & Darlene
>
>
>--
>FAQ on WWW:               http://www.contesting.com/ampsfaq.html
>Submissions:              amps@contesting.com
>Administrative requests:  amps-REQUEST@contesting.com
>Problems:                 owner-amps@contesting.com
>Search:                   http://www.contesting.com/km9p/search.htm
>


-
-  Rich...
R. Measures, 805-386-3734, AG6K, www.vcnet.com/measures  


--
FAQ on WWW:               http://www.contesting.com/ampsfaq.html
Submissions:              amps@contesting.com
Administrative requests:  amps-REQUEST@contesting.com
Problems:                 owner-amps@contesting.com
Search:                   http://www.contesting.com/km9p/search.htm


<Prev in Thread] Current Thread [Next in Thread>