>The reason I'm asking this is due to my lack of a capacitance tester.
>
Use a dipmeter to measure freq. of resonance with a +/- 5% inductor of
10 to 100 uH and calculate C.
>I have a Jennings UCS500, 7.5KV Vacuum Variable. I'm not sure if the bell
>it came with is original, so I think possibly the limit pin is wrong also.
>
>If I have the cap at minimum, should I be able to see air between the fixed
>and movable plates?
Yes, about one mm.
- later, Jay
Rich. Measures.,www.vcnet.com/measures, 805.386.3734
--
FAQ on WWW: http://www.contesting.com/ampfaq.html
Submissions: amps@contesting.com
Administrative requests: amps-REQUEST@contesting.com
Problems: owner-amps@contesting.com
Search: http://www.contesting.com/km9p/search.htm
|